Part No. HA026157 Issue 2
© Copyright Eurotherm Controls Limited 1997
All rights strictly reserved. No part of this document may be stored in a retrieval system, or any form or by any means without prior written permission from Eurotherm Controls Limited. Every effort has been
taken to ensure the accuracy of this specification. However in order to maintain our technological lead we are continuously improving our products which could, without notice, result in amendments or
omissions to this specification. We cannot accept responsibility for damage, injury, loss or expenses resulting therefrom.
EUROTHERM CONTROLS LIMITED
http://www.eurotherm.co.uk
UK SALES OFFICE
Eurotherm Controls Limited. Faraday Close, Durrington, Worthing, West Sussex BN13 3PL
Telephone Sales: (01903) 695888; Technical: (01903) 695777; Service: (01903) 695444
Fax (01903) 695666
Sales and support in over 30 countries worldwide
Enquiries/orders to: Eurotherm Controls Limited Export Dept., Faraday Close, Durrington, Worthing. West Sussex BN13 3PL.
Telephone (01903) 268500, Fax (01903) 265982
2132i
OP1
OP2
VH 85-264Vac
VL 20-29V dc or ac
Manual
XXX No manual
ENG English
FRA French
GER German
NED Dutch
SPA Spanish
SWE Swedish
ITA Italian
Logic I/O
Alarm 2 Relay Output
Function
ND Indicator only (Logic I/O
and Alarm relay will not
be fitted)
AL Indicator/alarm unit
(Logic I/O and alarm
output fitted)
Sensor Input Setpoint Min/Max Units
C °C
F °F
K Kelvin
X Linear input
Electrical connections
2132i 2116i
Specifications
Display:
4 digit, green, 10mm high characters
Supply voltage:
85-264Vac, 48-62Hz, or 20-29Vac/dc, 5watts max
Operating ambients:
0-55°C, 5-95%RH non-condensing
Output ratings:
Logic: 9Vdc, 12mA (non-isolated)
(Can be used as alarm output or alarm
acknowledge input)
Relay: 2A, 264V ac resistive
Calibration accuracy:
± 1°C or ± 0.25% of reading whichever is greater
48 mm
(1.89in)
48 mm (1.89in)
103 mm (4.01in)
Panel cut-out
- 0.0
+ 0.6
45 x 45 mm
Panel cut-out
- 0.0
+ 0.3
22.2 x 45 mm
103 mm (4.01in)
48 mm (1.89in)
24 mm
(0.95in)
Dimensions
2132i 2116i
Line
Neutral
Alarm 2
Relay Output
T/C
PT100
1A
1B
+
mA Input
Sensor inputs
OR
Alarm
ack/reset
-
V-
V+
+
-
AB
AA
N
L
2.49
Ω
Alarm 1
External
Relay
Module
Logic
I/O
24
24
20-29Vac/dc
Low voltage supply
85-264Vac
Ordering Code
Cold junction compensation:
>30 to 1 rejection of ambient temperature change
Input filtering:
Off-999.9 seconds
EMC standards:
Meets generic emissions standard EN50091-2 and
immunity standard EN50082-2 for industrial
environments
Safety standard:
Meets EN61010, installation category II Pollution
degree 2
Atmospheres:
Not suitable for use above 2000m or in explosive or
corrosive atmospheres
Line
Neutral
Alarm 2
Relay Output
L
N
AB
V+
V-
T/C
PT100
Logic
I/O
AA
+
-
1A
1B
+
-
mA Input
Sensor inputs
OR
Alarm
ack/reset
Alarm 1
External
Relay
Module
2.49
Ω
24
24
20-29Vac/dc
Low voltage supply
85-264Vac
- 0.0
+ 0.6
External Relay Module
XX Not fitted
R7 Fitted (Operated by the
logic output)
Input Adaptor
XX Not fitted
V1 0-10Vdc
A1 0-20mA sense resistor
(2.49Ω, 0.1%)
Supply Voltage
1.77 x 1.77in
- 0.00
+ 0.02
0.88 x 1.77in
- 0.0
+ 0.01
- 0.0
+ 0.02
2132i
2116i
note 1
Model
Number
Function
Supply
Voltage
Manual Logic I/O
Alarm 2
Relay O/P
Sensor
Input
note 2
Setpoint
Min.
note 2
Setpoint
Max.
Units
Ext. Relay
Module
Input
Adaptor
XX Disabled (note 1)
Logic input
AC Alarm ack/reset
KL Keylock
Non-latched alarm
FH High alarm 1
FL Low alarm 1
Latched alarm
HA High alarm 1
LA Low alarm 1
NW New alarm
XX Disabled (note 1)
Non-latched alarm
FH High alarm 2
FL Low alarm 2
AL High alarm 2 & low
alarm 3
Latched alarm
HA High alarm 2
LA Low alarm 2
AL High alarm 2 & low
alarm 3
NW New alarm
Thermocouples °C °F
J Type J -210 to 1200 340 to 2192
K Type K -200 to 1372 -325 to 2500
T Type T -200 to 400 -325 to 750
L Type L -200 to 900 -325 to 1650
N Type N -200 to 1300 -325 to 2370
R Type R -50 to 1768 -58 to 3200
S Type S -50 to 1768 -58 to 3200
B Type B -0 to 1820 32 to 3308
P Platinell II 0 to 1369 32 to 2496
Resistance thermometer
Z Pt100 -200 to 850 -325 to 1562
Custom downloaded inputs
C Type C - W5%Re/W26%Re 0 to 2319 32 to 4200
(default custom sensor)
D Type D - W3%Re/W25%Re 0 to 2399 32 to 4350
E E Thermocouple -200 to 999 -325 to 1830
1 Ni/Ni18%Mo 0 to 1399 32 to 2550
2 Pt20%Rh/Pt40%Rh 0 to 1870 32 to 3398
3 W/W26%Re (Englehard) 0 to 2000 32 to 3632
4 W/W26%Re (Hoskins) 0 to 2010 32 to 3650
5 W5%Re/W26%Re (Englehard)10 to 2300 50 to 4172
6 W5%Re/W26%Re (Bucose) 0 to 2000 32 to 3632
7 Pt10%Rh/Pt40%Rh 200 to 1800 32 to 3632
8 Exegen K80 I.R. pyrometer -45 to 650
Process inputs (linear)
M -9.99 to +80mV Scalable -1999 to 9999
Y 0 to 20mA (note 3) Scalable -1999 to 9999
A 4 to 20mA (note 3) Scalable -1999 to 9999
V 0 to 10Vdc (input adapter required) Scalable -1999 to 9999
Note 1. If ‘ND’ (Indicator only) is specified in
the function field then ‘XX’ must be entered in
the Logic Input/output field and the Alarm 2
Relay field.
Note 2. Setpoint min and max: include the
decimal position required in the display value;
up to one for temperature input, up to two for
process inputs.
Note 3. An external 1% current sense resistor
is supplied as standard. If greater accuracy is
required specify ‘A1’ in the Input Adaptor field.